Specifications | EK_Titel_E werb02 |
Business section |

Specifications | EK_Titel_E werb02 |
Business section |
Specifications | EK_Titel_E werb02 |
Outline | Contents DEHN – Worldwide. DEHN – Keeping you informed. SAFETY EQUIPMENT VOLTAGE DETECTORS Design of Voltage Detectors Application of Voltage Detectors in type-tested, factory assembled switchgear installations Selection Guide PHE III Voltage Detector PHE III Electronic Indicator Insulating Rods for PHE III Electronic Indicator PHE III Voltage Detector Kit PHE III Voltage Detector Kit PHE Voltage Detector PHG II Voltage Detector ASP Non-Contact Voltage Detector Kit HSA 205 Non-Contact Voltage Detector PHE/G d.c. Voltage Detector Electrodes Test Probes Spare Parts |
Suggested Link Details/Purchase | |
Content | SAFETY EQUIPMENT VOLTAGE DETECTORS 35www.dehn.de Electrodes,Test Probes Spare Parts PHE/G d.c. Voltage Detector Non-Contact Voltage Detector PHG II Voltage Detector PHE Voltage Detector PHE III Voltage Detector ASP Non-Contact Voltage Detector Kit Nominal voltage range 110 .420 kV / 50 Hz •For use in wet weather •For overhead lines and outdoor switching stations •With self-testing element •Visual and acoustic indication •Fast battery replacement without the use of additional tools ASP non-contact voltage detector used in an outdoor switching station. Technical Data IndicatorPlastic,fully insulated,black Electric field sensorPlastic,black Insulating rodGlass-fibre reinforced polyester tube, Ø30 mm,grey,with a handguard and hand strap for safe operation; Sealing unit with plug-in coupling for extending the handle IndicatorVisual:LED display and Acoustic:Intermittent acoustic signal Readiness for operationVisual:permanent green light Voltage presentVisual:Red flashing light and Acoustic:Intermittent acoustic signal No voltage presentVisual:permanent green light Operating temperature range– 25°C .+ 55°C Self-testing element The ASP electronic indicator has an integrated self-testing element that automatically tests the electronic circuit for correct operation (threshold) after switching on the indicator. Category ”S”and ”L” Category ”S”voltage detectors can only be used in outdoor installations. Category ”L”voltage detectors can only be used for overhead lines. Category ”S”/ ”L”voltage detectors can be used in both outdoor instal- lations and for overhead lines. Replacing the battery The 9 V E block battery can easily be replaced by hand without the need for additional tools.By simply unscrewing the plastic nut,access is allowed for fast and easy replacement.Low battery conditions of the ASP indicator are indicated by both LEDs illuminated and an acoustic signal when switching on the detector. isolator e.g. overhead line earthed protective fitting stranded conductor Application for overhead lines The green ring of the category ”L” ASP non-contact voltage detector with electric field sensor is used to make contact with the last earthed fitting in such a way that the electric field sensor points in the direction of the conductor cable fixed at the other end of the insulator. Application in outdoor switching stations The green ring of the category ”S”ASP non-contact voltage detector with electric field sensor is used to make contact with the lowest insulator plate at a right angle. If a protective fitting is located on the earth side,contact is made at the next possible insulator plate above the protective fitting. e.g. 110 kV switchgear without earth-sided protective fitting stranded conductor bracket e.g. 110 kV switchgear with earth-sided protective fitting bracket stranded conductor 90°90° |
Navigation | Previous Page / Next Page |
Following Datasheets | EK_2009_gesamt_D (258 pages) elau_compliancestatement_v1_0 (16 pages) ElectricEnergyEngineering-1 (2 pages) electromobility-siemensworld-06-2011 (2 pages) Elec_Apparatus_01 (6 pages) elegantes_engineering (2 pages) Elektr-Energietechnik (2 pages) elektrischemaschinenfrhybridantriebefrpersonenkraftwagenundnutzfahrzeuge-1 (8 pages) elektrischemaschinenfrhybridantriebefrpersonenkraftwagenundnutzfahrzeuge (8 pages) elektroantriebe_ohne_schaltschrank_ansteuern (2 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |