Specifications | 11-S8E1 hhartenstein |
Business section |

Specifications | 11-S8E1 hhartenstein |
Business section |
Specifications | 11-S8E1 hhartenstein |
Outline | Front Page Ordering Information Specifications Engineering Data Operation Dimensions Installation Precautions Contacting Omron |
Suggested Link Details/Purchase | |
Content | 3Switching Power Supply S82G Specifications Table – continued from previous page Power ratings30 W60 W100 W150 W Characteristics Operating temperatureSee Derating Curve in Engineering Data Storage temperature-20° to 85°C (-4° to 185°F) Humidity30 to 90% (storage humidity: 20 to 95%) Dielectric strength2200 VAC, 50/60 Hz, for 1 minute (between input terminals and output terminals/housing) 500 VDC for 1 minute (between output terminals and input terminals/housing) Insulation resistance100 MΩ min. (between output terminals and input terminals/housing) Vibration10 to 55 Hz, 0.75 mm double amplitude (approx. 4.5 G) in 3 directions, respectively for 2 hours Shock294 m/s2 294 m/s2 (30 G) in 6 directions, respectively 3 times Output indicatorRed LED Electro Magnetic InterferenceFCC Class B Mean Time Between Failures100,000 hours min. Approved standardsUL (E105544), CSA (LR63986), VDE 0160 Weight750 g max.850 g max.1,100 g max.2,000 g max. Note:A surge absorber is provided for the input circuit. To test the dielectric strength and insulation resistance of the power supply, re- move the short bar attached across the FG and ACG terminals. Engineering Data DERATING CURVE Load (%) Ambient Temperature ( C) Forced air cooling Natural air cooling Note:The derating curve differs depending on the mount- ing position of the Power Supply. The curve shown here was obtained with the Power Supply mounted in the standard position. Mounting Position – Standard Installation OVERLOAD PROTECTION The power supply is provided with an overload protection function that protects the load and the power supply from possible damages by overcurrent. When the output current rises above a set value (105 to 135% of the rated output current), the protection function is effected, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Output voltage (V) Output current (%) Rated output voltage |
Navigation | Previous Page / Next Page |
Following Datasheets | power_supply_brochure (2 pages) pps_datasheet-1 (13 pages) pp_series (2 pages) PR05-PCB_Brochure_5-20-11 (1 pages) pr36mf1_e (15 pages) pr36mf2_e (15 pages) PRAndersonPower-2 (2 pages) PRArcticSilicon (2 pages) PRCreeXlampXPG (2 pages) precidipcustomdesign (9 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |