Outline | 1 Parameters 1.1 Introduction to SINAMICS G110 System Parameters 1.2 Quick commissioning (P0010=1) 1.3 Parameter Description |
Suggested Link Details/Purchase | |
Content | Parameters11/2004 Parameter List SINAMICS G110 866SL3298-0BA11-0BP0 P2106 External fault via USS Min: 0 CStat: CUT Datatype: U16 Unit: -Def: 0 P-Group: COMMANDS Active: first confirm QuickComm.: No Max: 1 External fault from USS Link (r2037 Bit13) Possible Settings: 0 Disable 1 Enable Dependency: External fault from USS Link if PZD length is larger than 3 (P2012 > 3). Note: The source of external fault can be from digital input or from USS link. r2110[4] Warning number Min: - Datatype: U16 Unit: -Def: - P-Group: ALARMS Max: - Displays warning information. A maximum of 2 active warnings (indices 0 and 1) and 2 historical warnings (indices 2 and 3) may be viewed. Index: r2110[0] : Recent Warnings -, warning 1 r2110[1] : Recent Warnings -, warning 2 r2110[2] : Recent Warnings -1, warning 3 r2110[3] : Recent Warnings -1, warning 4 Note: - Indices 0 and 1 are not stored. - The keypad will flash while a warning is active. The LED indicates the warning status in this case. r2114[2] Run time counter Min: - Datatype: U16 Unit: -Def: - P-Group: ALARMS Max: - Displays run time counter. It is the total time the drive has been powered up. When power goes value is saved, then restored on power up. The run time counter r2114 will be calculate as followed: - Multiply the value in r2114[0], by 65536 and then add it to the value in r2114[1] (Total power up time = 65536 * r2114[0] + r2114[1] seconds). - The resultant answer will be in seconds. Index: r2114[0] : System Time, Seconds, Upper Word r2114[1] : System Time, Seconds, Lower Word Example: If r2114[0] = 1 & r2114[1] = 20864 We get 1 * 65536 + 20864 = 86400 seconds which equals 1 day. P2167 Switch-off frequency f_off Min: 0.00 CStat: CUT Datatype: Float Unit: Hz Def: 1.00 P-Group: ALARMSActive: Immediately QuickComm.: No Max: 10.00 Defines the threshold of the monitoring function |f_act| > P2167 (f_off). P2167 influences following functions: - If the actual frequency falls below this threshold and the time delay has expired, bit 1 in status word 2 (r0053) is reset. - If a OFF1 or OFF3 was applied and bit 1 is reset the inverter will disable the pulse (OFF2). Restriction: - The monitoring function |f_act| > P2167 (f_off) is not updated and pulses are not inhibited, if motor holding brake (MHB, P1215 = 1) is enabled. Level 3 Level 3 Level 3 Level 3 |
Navigation | Previous Page / Next Page |
Following Datasheets | G110_PLi_cz_1003_cz (84 pages) G110_strucny_CZ_0405_cz (28 pages) G130_General_diagram_en (4 pages) G130_Operating_Manual_Braking_Module_en (34 pages) Gesamtdoku_LON_A2_en (25 pages) gland_plate_en (1 pages) HB_GSM_4_1_0204_cz (61 pages) HB_GSM_4_1_Logo_0404_cz (58 pages) hcg_manual_en (18 pages) Help_cz (150 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |