
Specifications | |
Business section |
Specifications | |
Suggested Link Details/Purchase | |
Content | Siemens DA 21.1·20062/13 SIMOREG 6RA70 DC MASTERSystem Overview 2■Terminal assignments for basic units TypeTerminal designFunctionTerminalConnection values/comments Power section:Converters with •15 and 30 A: KDS10 PCB feed-through (screw-type terminal max. cross- section 10 mm2, stranded) Armature line input Protective conductor PE 1U1 1V1 1W1 U See technical data •60 to 280 A: 1U1, 1V1, 1W1: Through-hole for M8 (3 x 20 copper bus) 1C1, 1D1: Through-hole for M8 (5x 20 copper bus) Armature circuit/ motor connection 1C1 (1D1) 1D1 (1C1) •400 to 600 A: 1U1, 1V1, 1W1: Through-hole for M10 (5 x 30 copper bus) 1C1, 1D1: Through-hole for M10 (5 x 35 copper bus) •710 to 850 A: Through-hole for M12 (5 x 60 copper bus) •900 to 1200 A: Through-hole for M12 (10 x 60 copper bus) •1500 to 2200 A: 1U1, 1V1, 1W1: Through-hole for M12 (10 x 80 copper bus) 1C1, 1D1: Through-hole for M12 (10 x 50 copper bus) •2200 to 3000 A: 1U1, 1V1, 1W1: Through-hole for M12 (2 x copper bus 10 x 100) 1C1, 1D1: Through-hole for M12 (2 x copper bus 10 x 80) The converters are designed for a permanent power supply connection according to DIN VDE 0160 Section 6.5.2.1. PE conductor connection: Minimum cross-section 10 mm2 The conductor cross-sections must be determined according to the applicable regulations, e.g. DIN VDE 100 Part 523, DIN VDE 0276 Part 1000). Field circuit•15 to 850 A: MKDS PCB terminal block (screw-type terminal) max. cross- section 4 mm2 stranded Mains connection Field winding connection XF1-2/3U1 XF1-1/3W1 XF2-2/3C XF2-1/3D 2-ph. AC 400 to 460 V (+15%/–20%) 325 V rated DC voltage with 2-ph. AC 400 V mains connection •900 to 2000 A: G10/4 converter terminal (screw-type terminal) max. cross- section 10 mm2 stranded •2200 to 3000 A: UK16N converter terminal (screw-type terminal) max. cross- section 16 mm2 stranded Electronics power supply 1) •Plug-in terminal max. cross-section 1.5 mm2 stranded Incoming supply XP/5W1 XP/5N1 XP/5U12-ph. AC 380 to 460 V (+15%/–25%); n = 1 A (–35% for 1 min) or 1-ph. AC 190 to 230 V (+15%/–25%; n = 2 A Fan 2)Plug-in terminal (screw-type terminal) Max. cross-section 4mm2 stranded Incoming supply Protective conductor PE 4U1 4V1 4W U 3-ph. AC 400 V (±15%) For further information, see technical data Analog inputs, tacho inputs Plug-in terminal Max. cross-section 2.5mm2Tacho connection 8 to 270 V Analog ground M XT/103 XT/104 ±270 V; > 143 k Signs can be reversed and signals switched through by means of binary input functions. Safety shutdown (E-STOP) MSTB2.5 plug-in terminal Max. cross-section 2.5 mm2Supply for safety shutdown Safety shutdown – Switch – Pushbutton – Reset XS/106 XS/105 3) XS/107 3) XS/108 3) 24 V DC, max. load 50 mA, short-circuit-proof, evaluation via fault message F018 e = 20 mA NC contact e = 30 mA NO contact e = 10 mA Terminal assignments 1)Note: For converters with a power section supply voltage that lies outside the tolerance range (note max. permissible power section supply voltage), the electronics power supply, field circuit mains connection and fan connection must be adapted to AC 400 V via a transformer. An autotransformer is recommended for power sec- tion supply voltages up to 500 V. An isolating transformer must be used for power section supply voltages over 500 V. This isolating transformer must have a center tap that is connected to protec- tive earth PE. 2)On forced-ventilated converters 400 A 3)Note: Either terminal 105 or termi- nals 107 and 108 may be used. Terminal 105 is connected to terminal 106 in the delivery state. |
Navigation | Previous Page / Next Page |
Suggested Link Details/Purchase | |
Following Datasheets | ENG_47791 (4 pages) ENG_47792 (5 pages) ENG_47821 (3 pages) ENG_47990 (2 pages) ENG_48109 (4 pages) ENG_48112 (4 pages) ENG_48113 (4 pages) ENG_48114 (3 pages) ENG_48116 (1 pages) ENG_48831 (2 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |