Content | Siemens DA 21.1·20063/12 SIMOREG 6RA70 DC MASTERTechnical Data 3 ■3-ph. AC 830 V, 900 A to 1900 A, 1Q and 3-ph. AC 950 V, 2200 A, 1Q Type6RA70@@-6LS22-06RA70@@-4LS22-06RA70@@-4MS22-0 88939596 Rated supply voltage armature 1) V3-ph. AC 830 (+10% / –20%)3 AC 950 (+15%/-20%) Rated input current armature 2)A746124415751824 Rated supply voltage electronics supply V2-ph. AC 380 (–25%) to 460 (+15%); n=1 A or 1-ph. AC 190 (–25%) to 230 (+15%); n=2 A (–35% for 1 min) Rated supply voltage fan V3-ph. AC 400 (±10%) 50 Hz 3-ph. AC 460 (±10%) 60 Hz 3-ph. AC 400 (±10%) 50 Hz 3-ph. AC 460 (±10%) 60 Hz 50 Hz60 Hz50 Hz60 Hz Nominal fan currentA1.0 8)1.25 8)1.0 8)1.25 8) Air flow ratem3/h1300130024002400 Fan noise leveldBA83878387 Rated supply voltage field 1) V2-ph. AC 460 (+15 % / –20 %) Rated frequencyHz45 to 65 9) Rated DC voltage 1)V10001140 Rated DC currentA900150019002200 Overload capability 5)Max. 1.8 times rated DC current Rated outputkW900150019002508 Power loss at rated DC current (approx.) W46386778870011370 Rated DC voltage field 1)VMax. 375 Rated DC current fieldA304085 Operational ambient temperature °C0 to 40 at rated 3) separately cooled Storage and transport temperature°C–25 to +70 Installation altitude above sea level 1000 m at rated DC current 4) Dimensions (H x W x D)mm780 x 410 x 362880 x 450 x 500 See dimension drawing on Page9/49/59/6 Weight (approx.)kg80125 Converters for single-quadrant operation 1)The armature/field supply voltage can be less than the rated supply voltage armature/field (set with Parameter P078; for converters with 400 V rated voltage, input voltages of up to 85 V are permissible). The output voltage is reduced accordingly. The specified output DC voltage can be guaranteed up to undervoltages 5 % below the supply voltage (rated supply voltage armature/field). 2)Values apply to output rated DC current. 3)Load factor K1 (DC current) as a function of the coolant temperature (see P077 Operating Instructions, Section 11). K1 > 1 only permissible where K1 * K2 1st. overall reduction factor K = K1 * K2 (for K2 see Footnote 4). a)In spite of derating, converters of 400 A with enhanced cooling may be operated at an ambient or coolant temperature of 50 ºC only if the rated supply voltage of the con- verter fan is safely within the limited toler- ance range of 400 V +10% –15%. b)Not permissible when T400 or OP1S are used.Ambient or coolant tem- perature Load factor K1 In devices with self-cool- ing In devices with enhanced cooling +30 °C1.181.10 +35 °C1.121.05 +40 °C1.061.00 +45 °C1.000.95 +50 °C0.940.90 a) +55 °C0.88 +60 °C0.82 b) |
Navigation | Previous Page / Next Page |
Following Datasheets | ENG_43696 (1 pages) ENG_43697 (3 pages) ENG_43698 (1 pages) ENG_43699 (2 pages) ENG_43700 (1 pages) ENG_4663 (7 pages) ENG_47790 (4 pages) ENG_47791 (4 pages) ENG_47792 (5 pages) ENG_47821 (3 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |