Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |

Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |
Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | Functional Example No. MC-FE-I-002-V11-EN 413 Ex. No. Behavior when Emergency Stop is issued Emergency Stop is initiated using button S3 ( Emergency Stop ). This initiates that the drive is shut down according to stop Category 1 in compliance with EN 60204-1. ■A 0 signal is entered at contact 65 (controller enable RF) of the drive via the enable contacts of safety combination A1. The drive is immediately braked down to 0 speed and the pulses are cancelled. At the same time, the drop-out delay of timer relay K2a and the delay time of the safety relay A1 are started; the drive must have come to a standstill before they expire. ■The internal safety relay of the drive is no longer energized after the drop-out delay time of time relay K2a has expired (1st shutdown path!). ■After opening the safely delayed enable contact of safety combination A1, the internal line contactor of the rectifier unit is no longer energized and the drive is electrically iso- lated from the line supply (2nd shutdown path!). ■The checkback signal of the internal line contactor of the rec- tifier unit is monitored in the on circuit of safety combination A1. If the contactor does not drop-out due to an incorrect function, then the drive is prevented from restarting after an Emergency Stop. Behavior when the protective doors are opened Button S1 ( Off ) requests that the protective doors are opened. This initiates that the drive is shut down according to stop Category 1 in compliance with EN 60204-1. ■Contactor K3 is no longer energized and a 0 signal is entered at contact 65 (controller enable RF) of the drive via its contact (NO contact). The drive is immediately braked down to 0 speed and the pulses are cancelled. At the same time, the drop-out delay of time relay K2a is started and before this time has expired, the drive must have come to a standstill. ■After the drop-out delay time of time relay K2a has expired, the internal safety relay of the drive is no longer energized (1st shutdown path!). At the same time, the latch (tum- bler) Y1 of the protective doors is opened. ■When the protective doors are opened the safety monitor- ing A2 of the safety circuit is interrupted. Before the selected delay time of safety combination A2 has expired, the internal safety relay of the drive must have already dropped-out. Its checkback signal contacts AS1/2 indicate that the drive is in a safe condition. ■After the selected delay time has expired, the safely delayed enable contacts of the safety combination A2 open. ■If the internal safety relay of the drive is functioning cor- rectly, its checkback signal contacts AS1/2 are closed and the internal line contactor of the rectifier unit does not drop-out. If the internal safety relay does not function cor- rectly, its checkback signal contacts AS1/2 are not closed, the internal line contactor of the rectifier unit drops-out and isolates the drive from the line supply (2nd shutdown path!). Powering-up the drive The drive can be started when the protective doors are closed and Emergency Stop button S3 is released. ■When pressing button S2 ( On ), safety combination A1 is brought into the operational state. The coil of latch (tum- bler) Y1 is no longer energized, the protective doors are interlocked. Safety combination A2 is again in an opera- tional state. The internal line contactor of the rectifier unit is energized. ■Contactor K3 is energized and latches and at the same time, time relay K2a is energized. The integrated safety relay is energized and a 1 signal is entered at contact 65 (controller enable) of the drive. The drive restarts. 2.1 |
Navigation | Previous Page / Next Page |
Suggested Link Details/Purchase | |
Following Datasheets | Safety_F_F-H_Conf_Progr (338 pages) Safety_Integrated_2009_EN (544 pages) Safety_Integrated_Functional_Examples_2007EN (512 pages) Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |