Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |

Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |
Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | 360Functional Example No. AS-FE-I-011-V10-EN Ex. No.11Process: F-communication error Precondition In the safety program the user acknowledges the reintegra- tion by providing ACK_REI with a positive edge. Process sequences At F-communication error (e.g. due to disconnecting F-CPU and ET200) the entire affected F-I/O is passivated. If the error has been removed the F-I/O is only reintegrated after acknowl- edgement by the user. This applies irrespective of the ACK_NEC value. The following figure and table illustrates the process sequence. Explanations for the table: (*1): BF-LED at IM 151 HF is on. BF-LED at F-CPU is blinking. (*2): The BF-LEDs are off. Note For F-communication error automatic reintegration is not possible! F-I/O passivated (2) Error occurs F-I/O remains passivated (3) Error occurs User acknowledged F-I/O not passivated (1) F-I/O reintegrated (4) Numbers in brackets indicate the state. State Description of status and eventsF-I/O data block F-DI and F-DO / SF-LED A: ACK_NEC B: ACK_REI C: PASS_OUT D: QBAD E: ACK_REQ F: SF-LED ABCDEF 1F-I/O is not passivated.x00000 Event: Error occurs. 2F-module is passivated.x01100 (*1) Event: Error removed. 3F-I/O has recognized that the error has been removed.x01110 (*2) Event: User acknowledges (positive edge).0->1 4F-system has reintegrated the F-I/O.xx0000 |
Navigation | Previous Page / Next Page |
Following Datasheets | Safety_F_F-H_Conf_Progr (338 pages) Safety_Integrated_2009_EN (544 pages) Safety_Integrated_Functional_Examples_2007EN (512 pages) Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |