Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |

Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |
Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | 358Functional Example No. AS-FE-I-011-V10-EN Ex. No.11Process: Channel / module error (automatic reintegration) Precondition The user has set ACK_NEC = 0 in the safety program. Process sequences If an error is pending at the F-module (channel or module er- ror), the F-module is passivated by the F-system. If the error has been removed and ACK_NEC = 0 , the F-module of the F-system is automatically reintegrated. The following figure and table illustrates the process se- quence. F-module passivated (3, 4) Error occurs Error removed F-module not passivated (1, 2) F-module reintegrated (5) Numbers in brackets indicate the state. State Description of status and events F-I/O-module data block / SF- LED A: ACK_NEC B: PASS_OUT C: QBAD D: SF-LED ABCD 1F-module is not passivated.0000 Event: error occurs at the F-module. 2F-module has recognized the error.0001 Event: F-system recognizes the error at the F-module. 3F-system has passivated F-module.0111 Event: Removing the error at the F-module. 4F-module has recognized that the error has been removed0110 Event: F-system recognizes that the error at the F-module has been removed. 5F-system has reintegrated the F-module.0000 |
Navigation | Previous Page / Next Page |
Following Datasheets | Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) safe_ethernet (2 pages) SAG_D_op061212_1425057 (52 pages) Sail_Drive_2010_09 (4 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |