Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | Functional Example No. AS-FE-I-011-V10-EN 355 Ex. No.11How is the passivation of channels realized? Precondition Passivation of channels requires: ■S7 Distributed Safety V5.4, and S7 F Configuration Pack V5.4 + SP1 ■ F-modules which support the passivation of channels Currently, the following F-modules support passivation of channels: Configuration In the hardware configuration of STEP 7 the following project settings options exist: ■ Passivate the entire module ■ Passivate channel . The configuration is made in the following tab of the F-I/O- module: ■ Module parameter -> Behavior after channel error At page 323 you find two respective examples: ■F-DI with Passivate the entire module ■F-DI with Passivate the channel The respective configurations are shaded. Reintegration (of entire module or channel) What happens during reintegration? Reintegration has the following effect: Which types of reintegration exist? The reintegration of an F-module can occur in two different ways (see page 356): ■manually: ■automatically: During manual reintegration, the user must acknowledge in the safety program for the reintegration of the F-system to be performed. ACK_REI (see page 351) must be provided with a positive edge for this. During automatic reintegration, the F-system integrates the F- module if the error causing the passivation has been removed. The user needs not acknowledge in the safety program. Whether reintegration occurs manually or automatically is controlled via ACK_NEC (see page351 ): ■ACK_NEC = 1: Manual (Default value) ■ACK_NEC = 0: Automatic (must be set in the safety program by the user) ET 200F moduleDescription ET 200 S 6ES7138-4FA02-0AB04/8 F-DI DC24V PROFIsafe 6ES7138-4FB02-0AB04 F-DO DC24V/2A PROFIsafe 6ES7138-4CF02-0AB0PM-E F pm DC24V PROFIsafe 6ES7138-4CF41-0AB0PM-E F pp DC24V PROFIsafe ET 200 M6ES7326-2BF01-0AB0SM 326F; DO 10xDC24V/2A 6ES7326-2BF40-0AB0SM 326F; DO 8x DC 24V/2A P/M 6ES7326-1RF00-0AB0SM 326F; DI 8xNAMUR 6ES7336-1HE00-0AB0SM 336F; AI 6x13Bit ET 200 PRO6ES7148-4FA00-0XB08/16 F-DI DC24V PROFIsafe 6ES7148-4FC00-0XB04/8 F-DI 4 F-DO DC24V/2A PROFIsafe ET 200 ECO6ES7148-3FA00-0XB04/8 F-DI DC24V PROFIsafe ReintegrationEffect of reintegration: F-input module (F-DI)The safety program is provided with the process values pending at the input via the process image of the inputs. F-output module (F-DO)The output values provided by the safety program in the process im- age of the outputs are transmitted to the outputs. Warning Automatic reintegration is only permitted if an auto- matic startup of the plant is not possible after the error has been removed. |
Navigation | Previous Page / Next Page |
Following Datasheets | Safety_F_F-H_Conf_Progr (338 pages) Safety_Integrated_2009_EN (544 pages) Safety_Integrated_Functional_Examples_2007EN (512 pages) Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |