Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |

Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |
Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | Functional Example No. AS-FE-I-006-V10-EN 239 Ex. No. Important hardware component settings Below, several important settings from the hardware configu- ration of STEP 7 are shown to provide you with an overview. These settings are available in the included STEP 7 project. It is basically possible to change these settings (e.g. due to indi- vidual requirements), but please consider the following note: Warning! The settings shown below contribute to meet the re- quirements of Safety Category 4. Changes of the set- tings may cause a loss of the safety functions. If you implement changes (e.g. add an additional module), the sample code has to be adapted accordingly. Overview picture The PROFIBUS adress at IM 151HF is set using DIP-switches. Settings of the CPU 315F-2DP The settings are displayed after double-clicking CPU 315F-2 DP (see Overview picture ). Default value: 100 ms. It has to be observed that the F moni- toring time must be larger than the call time of OB 35. Available in the Protection tab. A password has to be allocated in order to be able to set the parameter CPU Contains Safety Program . It is only in this case that all required F blocks for safe operation of the F mod- ules are generated during compiling the hardware configura- tion of STEP 7. Password used here: siemens 6 |
Navigation | Previous Page / Next Page |
Following Datasheets | Safety_F_F-H_Conf_Progr (338 pages) Safety_Integrated_2009_EN (544 pages) Safety_Integrated_Functional_Examples_2007EN (512 pages) Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |