Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | 204Functional Example No. AS-FE-I-003-V10-EN Ex. No. The acknowledgement for the enable is given at the input ACK_NEC depending on the parameters: ■For ACK_NEC = 0 an automatic acknowledgement is given (as implemented in this example). ■For ACK_NEC = 1 an enable requires acknowledging ACK at the input by means of a rising edge. In order for the F application block to recognize whether the inputs IN1 and IN2 are only 0 due to a passivation of the re- spective F-periphery, you must supply the inputs QBAD_IN1 and QBAD_IN2 with the variable QBAD of the respective F pe- riphery DB. This prevents for example that for a passivation of the F-periphery the safety door must be completely opened prior to acknowledgement. Warning! The parameterization of the variables ACK_NEC=0 is only permitted, if an automatic restart of the respec- tive process is excluded otherwise. Should you supplement the example by means of a manual acknowledgement, please note the following: Note For safety door applications, the acknowledge signal must be read via a failsafe input module (F-DI), if it is an accessible hazardous area. For a non-accessible hazard- ous area, the acknowledge signal can also be read via a standard input module. The F-application module supports the requirements accord- ing to EN954-1 and EN 1088. After restarting the F system, the enable signal Q is reset to 0 . The acknowledgement for the enable is given at the input OPEN_NEC and ACK_NEC depending on the parameters: ■For OPEN_NEC = 0 an automatic acknowledge is given independent of ACK_NEC, as soon as both inputs IN1 and IN2 have the signal status 1 for the first time after reinte- gration of the respective F periphery (safety door is closed). In this example this variant has not been activated. ■For OPEN_NEC = 1 or if at least on of both inputs IN1 and IN2 have the signal status 0 even after reintegration of the respective periphery, an automatic acknowledgement is given depending on ACK_NEC, or the enable requires acknowledging ACK at the input by means of a rising edge. Prior to acknowledgement both inputs IN1 and IN2 must have had the signal status 0 (safety door completely opened) and subsequently signal status 1 (safety door closed). Warning! The parameterization of the variables OPEN_NEC=0 is only permitted, if an automatic restart of the re- spective process is excluded otherwise. At the output DIAG a non-failsafe information on occurred er- rors is provided for service purposes. You can read it out via HMI systems or if necessary evaluate them in your standard user program. Note The safety program does not allow accessing the output DIAG! FB COORDINATION (FB1, DB1) After processing the FB 217, processing is continued in FB 1: Network 2 The machine must only start at valid enable from FB 217 (#RE- LEASE= 1 ) and the start request ( COND1 = 1 ) from the standard user program. Additionally the tumbler (E_MAGNET) must be monitored (see Network 3 below). The machine stops by a failure locking. Network 3 B H * + - 7- *. . : - ) $#-3 ) B GH H * + )- $(- ) ) *2:) . : - 3 |
Navigation | Previous Page / Next Page |
Suggested Link Details/Purchase | |
Following Datasheets | Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) safe_ethernet (2 pages) SAG_D_op061212_1425057 (52 pages) Sail_Drive_2010_09 (4 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |