Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |

Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Business section |
Specifications | Safety Integrated Functional Examples - February 2007 A&D CD MM 2 |
Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | 182Functional Example No. AS-FE-I-002-V10-EN Ex. No. Setup and Wiring In order to set up and wire the functional example, it is abso- lutely necessary to consider the following note: Warning! In order to meet the requirements of Safety Category 4, it is obligatory to read back the process signal to the actuator. Read back is not implemented in this example. The actuator in this example is an indicator light sim- ulating a machine. If other actuators are used, read back has to be ensured by the user. The Safety Inte- grated Functional Example No. 7 „Integration of the Readback Signal in an Application of Category 4 acc. to EN 954-1“ provides a detailed description of Read back . An overview of the hardware structure The arrangement to implement the safety door interlock con- sists of a PROFIBUS configuration. A failsafe S7-CPU is used as DP master, an ET 200S as DP slave. Below, the wiring of conven- tional modules is shown only partly to provide greater clarity. Warning! A speed or standstill monitor for monitoring hazard- ous slowing down of a machine is simulated in this example with a button (NO) which is connected as single-channel to the failsafe input module (F-DI). When using real speed or standstill monitors they must be connected to the F-DI as double-channels (1oo2 evaluation). Note The high feature electronic modules can also be re- placed by standard modules. Wiring of the hardware components Requirements: The power supplies are supplied with 230V AC. First check the addresses set at the hardware components listed below: Note The DP interface of the CPU 315F must be connected with the DP interface of the IM 151 HF. Note The wiring of the hardware is illustrated below. In the following table, the hardware components occurring several times are numbered so they can be allocated in the subsequent wiring plan. #$% &# () 0*+ 1) )/*+ 21 2 , , )/*+0*+1) ,/! +, ( 1) ,/!)/* 3 43 3 , 2 Hardware component Adress to be set Note IM 151 High Feature6 (PROFIBUS ad- dress) Can be changed F-DISwitch position: 1111111110 The PROFIsafe addresses are automatically assigned dur- ing configuring the failsafe modules in STEP7. The PROFIsafe addresses 1 to 1022 are permissible. Please make sure that the setting at the address switch (DIL switch) on the side of the module corresponds to the PROFIsafe address in the hardware configuration of STEP7. F-DOSwitch position: 1111111101 2 |
Navigation | Previous Page / Next Page |
Following Datasheets | Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) safe_ethernet (2 pages) SAG_D_op061212_1425057 (52 pages) Sail_Drive_2010_09 (4 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |