Outline | Safety Integrated Functional Examples - March 2007 Contents Safety-related controls - SIRIUS Safety Integrated Functional examples with SIRIUS 3TK28 safety relay CD-FE-I-001-V11-EN - E-Stop with manual start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-002-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1with a SIRIUS 3TK28 safety relay CD-FE-I-003-V11-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-004-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay CD-FE-I-017-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-018-V10-EN - E-Stop with monitored start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relay CD-FE-I-019-V10-EN - E-Stop with monitored start Category 4 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-020-V10-EN - Protective door monitoring with automatic start Category 2acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-021-V10-EN - Protective door monitoring with automatic start Category 2 acc. to EN 954-1 with/without operational switching with a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-022-V10-EN - Protective door monitoring with automatic start Category 4 acc. to EN 954-1 with/without operational switching using a SIRIUS 3TK28 safety relay with contactor relays CD-FE-I-023-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 2 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay CD-FE-I-024-V10-EN - E-Stop with monitored start, protective door monitoring with automatic start and service mode, Category 4 acc. to EN 954-1 with a SIRIUS 3TK2845 safety relay |
Suggested Link Details/Purchase | |
Content | 12Functional Example No. CD-FE-I-017-V10-EN Ex. No.E-Stop with monitored start Category 2 acc. to EN 954-1 with a SIRIUS 3TK28 safety relay with contactor relays Function Description of the functionality If people (in production technology) are close to machines, then they must be protected using the appropriate equip- ment. The E-Stop command device represents a widely estab- lished component that protects people, plants/systems and the environment against potential hazards. In this Safety Functional Example, the E-Stop command device with a positively-opening contact is monitored by a SIRIUS 3TK28 safety relay with contactor relays according to Category 2 in compliance with EN 954-1. If the E-Stop command device is actuated, the safety relay shuts down via its contactor relays with positively-opening contacts according to Stop Category 0 in compliance with EN 60204-1. Before restarting or acknowl- edging the E-Stop shutdown using the start button, a check is made as to whether the E-Stop command device contact is closed and the contactor relays of the safety relay been de-en- ergized. Note Equipment, functional aspects and design guidelines for E-Stop command devices are provided in EN 418 (EN ISO 13850 in draft status). Advantages/customer benefits ■Pure hardware engineering without having to config- ure/program software ■A low scope of simple wiring ■Space-saving design using our compact safety relay ■Can be simply expanded using expansion devices Required components Hardware components Note The functionality was tested using the specified hard- ware components. Products that are similar but deviate from the list above can be used (e.g. a different 3TK28 safety relay). However, in this case, please carefully note that it may be necessary to make modifications as to how the hardware components are connected-up (e.g. another connection assignment). ComponentTypeMRPD / Ordering dataQtyManufacturer E-StopMushroom head pushbutton, 1 NC, 40 mm, with yellow upper section without protective collar 3SB3 801-0DG31Siemens AG Safety relay with contactor relays3TK283TK2850-1BB401 Start buttonEmpty housing of a command point3SB3 801-0AA31 1NO contact for base-mounting3SB3 420-OB1 Pushbutton, black with flat actuator, 22 mm nom- inal diameter 3SB3 000-0AA111 Optional: Inscription plate Start 3SB3 906-1EL1 1.5 |
Navigation | Previous Page / Next Page |
Following Datasheets | Safety_S7_DS_Conf_Progr (318 pages) Safety_S7_DS_GetSta (42 pages) Safety_Short_Catalog_2007 (428 pages) Safety_System_Manual (345 pages) Safety_System_Manual_Suplement_en (92 pages) Safety_terminologia_i_standardy (52 pages) Safety_Terms_Standards (52 pages) safe_ethernet (2 pages) SAG_D_op061212_1425057 (52 pages) Sail_Drive_2010_09 (4 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |