
Specifications | |
Business section |
Specifications | |
Suggested Link Details/Purchase | |
Content | PLASMACCD1 Spectrometer for Plasmalab Systems0909 A CCD spectrometer is an extremely useful addition to any plasma tool, since it can provide not only a process endpointing capability, but also a large amount of plasma spectroscopy information - used for monitoring the species within the plasma. The newly introduced CCD1 spectrometer provides a cost-effective route to general purpose endpointing and spectroscopy, without compromising on resolution or signal strength. A spectrometer captures the light emitted from the plasma via a viewport (usually on the rear of the chamber), and provides information on the light intensity at each emission wavelength. The CCD1 is a UV/VIS CCD spectrometer that can monitor a wide range of plasma emissions - between the wavelengths 200nm-880nm. This allows the user to monitor all common plasma emission peaks in the UV and visible wavelengths. The CCD1 unit provides good wavelength resolution (<2nm FWHM), hence allowing closely grouped emission lines to be individually identi ed. A window protector is provided in the CCD1 kit to minimise window fogging or coating and hence allow more repeatable endpointing and spectroscopy analysis in aggressive or depositing processes. The kit also includes a quartz viewport assembly (to allow UV detection), silica bre optic cable, a spectroscopy software package, and integration of the CCD1 unit to OIPT’s front-end software to allow process endpointing. The CCD1 unit can be used in one of two ways: Endpoint detection Process endpointing is achieved via OIPT’s front-end software. An example endpoint trace is given in Figure1. Either a single intensity or a ratio of two intensities can be used for the endpoint signal. The intensities of up to three user-selectable wavelengths can be displayed and datalogged. The intensity and smoothing parameters of the CCD signal can be adjusted via the integration time, number of samples to average, and boxcar width settings. Typical integration times are 5-100msecs for ICP plasmas, and 100msecs to 1sec for RIE or PECVD plasmas, depending on power levels used and assuming a clean window and an unobstructed view of the plasma. Viewing the emission spectrum The plasma emission spectrum can be viewed and recorded using the provided spectroscopy software package. This allows the user to monitor the species present in the plasma, and hence to gain a greater understanding of the process and its performance. This can be very useful for process optimisation, chamber condition monitoring, and as a process/system health check. The bene ts of plasma spectroscopy can be most easily displayed by showing examples of potential causes of process fault conditions and their ease of detection via spectroscopy. In the following examples a reference spectrum was captured and then the process or system adjusted to simulate a process/system change (see Figures 2 and 3). In each case the change in spectra can be clearly seen and its cause determined. The CCD1 spectrometer is now available as a system option on new Plasmalab tools, and can be offered as an upgrade to systems in the eld, dependent on the system age, type, and con guration. Andy Goodyear, Principal Applications Specialist, OIPT Figure 1. Endpointing using the CCD1. Figure 2. Effect of a contaminated chamber (polymer) on emission spectrum. Figure 3. Effect of a gas flow error on emission spectrum. PROCESSNEWS 5 |
Suggested Link Details/Purchase | |
Following Datasheets | cmi900_brochure (6 pages) Company_Profile_August_2011 (1 pages) consumables-xrf-catalogue-jan2009 (26 pages) Control_system_upgrade_flyer (2 pages) Cryogenic_Systems_Brochure (4 pages) Dry_Pump_N2_flyer (2 pages) EBSD_3D_AP_note (4 pages) EBSD_AppNote108_Pearl (6 pages) EBSD2012_registration (1 pages) Energy_Policy (1 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |