Specifications | MPS_CEF400-112C.B19.indd JParks |
Business section |
|

Specifications | MPS_CEF400-112C.B19.indd JParks |
Business section |
|
Specifications | MPS_CEF400-112C.B19.indd JParks |
Suggested Link Details/Purchase |
|
Content | FEATURES 400W continuous output power Low profi le (1U) IEC EN61000-3-2 compliance Remote sense compensation AC Power Fail signal DC Power Good signal Remote Inhibit control Droop current share Built-in OR-ing FET I2C interface 5V Standby Integrated cooling fan (variable speed) Over-voltage protection Over-current protection Thermal overload protection OUTPUT CHARACTERISTICS Output VoltageParameterConditionsMin.Typ.Max.Units 12V Voltage Set Point Accuracy17A load12.0812.12512.16VDCLine and Load Regulation11.7512.45 Ripple Voltage & Noise120MHz Bandwidth175mV p-p Rated Output Current33.3A 5Vsb Voltage Set Point Accuracy4.8555.15VDCLine and Load Regulation4.855.15 Ripple Voltage & Noise120MHz Bandwidth50mV p-p Rated Output Current1.3A GENERAL ParameterConditionsMin.Typ.Max.Units Remote SenseSum of +ve & -ve drops500mV EfficiencyFull load, high line83% Turn on Delay2s Transient Response 12V Ramp 1A/μs 33% step±375mV5Vsb Ramp 1A/μs 33% step±40 Current Sharing Accuracy 200-720W load (2 in parallel)45/55 %96-200W load (2 in parallel)40/60 50-96W load (2 in parallel)20/80 24-50W load (2 in parallel)10/90 Hold-up Time, to 10.8V400W, 120VAC line20ms IsolationOutput to Chassis-Basic500VrmsInput to Chassis-Basic1500 Temperature CoefficientFull load and 100VAC input0.02% / °C 1 Ripple and noise are measured with 0.1 μF of ceramic capacitance and 10 μF of tantalum capacitance on each of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial cable with 50Ω scope termination is used. PROTECTION CHARACTERISTICS ParameterOutput VoltageConditionsMin.Typ.Max.Units Over Voltage 12V Latching14.06514.514.935V Over CurrentAuto-restart363842A Short Circuit The 12V output shall current limit and shutdown during a shorted output condition, and shall automatically restart after the short is removed. Over Voltage5VsbLatching5.66V Over CurrentAuto-restart1.42.12.65A Over-temperatureUnitAuto-restartUnit shall self-protect against excessive internal temperatures and automatically recover. Input UndervoltageNo damage will be sustained by operation at voltages below the specified input operating voltage range. DESCRIPTION The CEF400-112C is a 400W active power- factor-corrected (PFC) front-end power supply for distributed power architecture (DPA) sys- tems requiring high power density in a 1U low profi le package. The built-in OR-ing FET allows the power supply to operate in active current sharing mode for redundant (N+1) operation. Additional features include I2C interface, built- in fan and a 5V standby auxiliary output. The CEF400-112 provides reliable 12V bulk power for Information Technology Equipment and Industrial Applications. INPUT CHARACTERISTICS ParameterConditionsMin.Typ.Max.Units Input Voltage Operating Range (AC)85264VAC Input Frequency4763Hz Turn-on Input VoltageRamp up7685VACTurn-off Input VoltageRamp down6378 Maximum Input Current1.756.5Arms Inrush Current20Apk Power FactorIEC EN61000-3-2 compliant Leakage Current264 VAC input0.90mA PRODUCT SPECIFICATIONS email: sales@murata-ps.com 04 Apr 2011 MPS_CEF400-112C.B19 Page 1 of 3 CEF400-112C 400 Watt Open Frame Single Output AC/DC Switching Power Supply www.murata-ps.com For full details go to www.murata-ps.com/rohs Ḥ www.murata-ps.com |
Navigation | Previous Page / Next Page |
Suggested Link Details/Purchase |
|
Following Datasheets | CEG_Series-WWTP_Cogeneration (5 pages) Celestica_PIP (2 pages) Cellular_Notch_Final_0507 (2 pages) CEN-100-SPEC (3 pages) CEN-60-spec (3 pages) CEN-75-spec (3 pages) ceramic_bandpass_filters (10 pages) CERT-0042168-3 (1 pages) CERT-0042315 (1 pages) CERT-0045007 (1 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |