Specifications | 100W AC-DC MIL COTS AC-DC Power Supplies Rugged MIL COTS: 100W AC-DC Updated May10,2011 rugged power supplies, COTS, PFC, EMI Martek Power |
Business section |
|

Specifications | 100W AC-DC MIL COTS AC-DC Power Supplies Rugged MIL COTS: 100W AC-DC Updated May10,2011 rugged power supplies, COTS, PFC, EMI Martek Power |
Business section |
|
Specifications | 100W AC-DC MIL COTS AC-DC Power Supplies Rugged MIL COTS: 100W AC-DC Updated May10,2011 rugged power supplies, COTS, PFC, EMI Martek Power |
Suggested Link Details/Purchase |
|
Content | PF100 100 Watts Output Power ACTIVEPOWERFACTORCORRECTION& HARMONICATTENUATIONMODULE Nominal No Load Voltage Setting Output Power (Full Load) Load Regulation (No Load - Full Load) Line Regulation (Low Line -High Line) Ripple P - P (60 Hz/115 VAC input) Overvoltage Protection (%of Output) Transient Response: 25 - 75 - 25% or 50 -100 - 50% step load Overshoot / Undershoot Recovery time (to 2% of Vout) Temperature Drift Output (Holdup) Capacitance Min. 103 Typ. 105 ±6.3 0.01 Max. 100 2.2 1 3.5 110 200 0.02 Units V W % Vout % Vout % Vout % Vou % Vout mS %/°C INPUT CHARACTERISTICS FEATURES OUTPUT CHARACTERISTICS Input Voltage (Single Phase) Input Frequency Range Inrush Current @115 Vrms @240 Vrms Power factor at Full Load 115Vin/ 60 - 400Hz 115Vin/ 800Hz 230Vin/ 50Hz 230Vin/ 400Hz 230Vin/ 800Hz Efficiency at Full Load 115Vin/ 60Hz 115Vin/ 400Hz 230Vin/ 50Hz 230Vin/ 400Hz 230Vin/ 800Hz Min. 85 45 0.98 0.94 0.97 0.92 0.79 92 91 92 92 92 Typ. 0.99 0.96 0.99 0.93 0.80 93 92 93 93 93 Max. 265 800 3 5 Units VAC Hz A A % % % % % HOW TO ORDER •• Meets all Requirements of MIL - STD - 1399, section 300A •• Meets CE01 and CE101 of MIL - STD - 461 without external filter •• Meets all requirements of MIL - STD - 704E •• Meets all requirements of ABD0100.1.8.1 •• Non-latching Over Temperature Protection •• Non-latching Output Overvoltage Protection •• Output short circuit protection, automatic recovery after short circuit removal •• Isolated Output DC Good TTL Signal(Open collector) •• Full 100 Watts of output power from 85 VAC to 265 VAC and up to 100°C baseplate temperature •• Utilizes non isolated boost topology •• Dual Nominal Voltage setting: 275V for 85 - 170 Vrms Input 380V from 180 - 264 Vrms Input •• Environmental Screening available All specifications are typical @+25°C with nominal input voltage under full output load conditions and holdup capacitance of 100 µF, unless otherwise noted. Specifications subject to change without notice. Series Unscreened (I) or Screened (M) Total Output Power Options: A - Pins out baseplate of unit C - Thru hole inserts (0.115DIA) I - M2.5 inserts PFI 100- A Not Included (specs are based on 100µF) www.martekpower.com >> 2 1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com 273 or 380278 or 385 |
Navigation | Previous Page / Next Page |
Following Datasheets | 367_2-1 (4 pages) 371-1 (4 pages) 372210 (1 pages) 372214 (1 pages) 3725fa_1 (20 pages) 3726fb_1 (16 pages) 375-1 (4 pages) 38-1_3 (1 pages) 38_3 (2 pages) 3818hv (1 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |