Specifications | GP_VD130_NA_Installation_Guide_English Panasonic |
Business section |

Specifications | GP_VD130_NA_Installation_Guide_English Panasonic |
Business section |
Specifications | GP_VD130_NA_Installation_Guide_English Panasonic |
Outline | Safety precautions Contents Before use Characteristics Accessories Installation precautions Operating precautions Concerning the IR repeater function Parts and their functions Installation Connections How to turn the power on and off Factory setting Troubleshooting Appearance Specifications |
Suggested Link Details/Purchase | |
Content | 17 How to turn the power on and off pwTurning the power on ppThis unit does not have a power switch. Its power is turned on when power is supplied to the unit. Unit’s power OFF Status display lamp: Off Power is supplied. When the power of the HD Visual Communication Unit has been turned on and the unit has been connected properly (about 30 seconds after) Standby mode Status display lamp: Orange Power ON mode Status display lamp: Green ppThe camera moves so that it is positioned at the home position. pwTurning the power off ppWhen the supply of power to the unit is cut off, the unit’s power is turned off. The power can be turned off regardless of the unit’s mode (standby mode or power ON mode). pwConcerning the mode transitions [Description of each mode] ModeStatus Standby mode Status display lamp: Orange When the HD Visual Communication Unit is in one of the statuses described below: ppHD Visual Communication Unit is in screen standby mode.* ppThe power of the HD Visual Communication Unit is OFF or the camera has not been connected to the HD Visual Communication Unit. * When the administrator menu settings of the HD Visual Communication Unit are used to select [HDMI Settings] followed by [Standby] and then [Standby] is set from [OFF] to [ON], the transition of the status of the camera mode becomes linked with the screen standby status of the unit. For details of the screen standby function, refer to the operating instructions of the HD Visual Communication Unit. Power ON mode Status display lamp: Green Status in which the camera has been connected properly to the HD Visual Communication Unit and can be controlled The transition of the status of the camera mode is linked with the status of the HD Visual Communication Unit. [Linkage with the screen standby status of the HD Visual Communication Unit] When the [Video Out On/Off] button on the remote controller is pressed, etc. Standby mode Status display lamp: Orange Power ON mode Status display lamp: Green ppThe camera is moved so that it is positioned toward the back. ppThe camera’s direction is returned to the position before the transition to the standby mode. When the [Video Out On/Off] button on the remote controller is pressed, etc. [Linkage with the status of the connection with the HD Visual Communication Unit] Standby mode Status display lamp: Orange Power ON mode Status display lamp: Green ppThe camera is moved so that it is positioned toward the back. HD Visual Communication Unit’s power OFF/ HDMI cable not connected* * Mode transition occurs about 60 seconds after the “HD Visual Communication Unit’s power OFF/HDMI cable not connected” linkage has been detected. Connection of the HDMI cable with the HD Visual Communication Unit’s power ON/Power of the HD Visual Communication Unit is ON while the HDMI cable is connected. ppThe camera’s direction is returned to the position before the transition to the standby mode. |
Navigation | Previous Page / Next Page |
Following Datasheets | GP_VD130_NA_Installation_Guide_English (24 pages) GP_VD130_NA_Installation_Guide_French-1 (24 pages) GP_VD130_NA_Installation_Guide_French (24 pages) GP_VD130_NA_Installation_Guide_Portuguese-1 (24 pages) GP_VD130_NA_Installation_Guide_Portuguese (24 pages) GP_VD130_NA_Installation_Guide_Spanish-1 (24 pages) GP_VD130_NA_Installation_Guide_Spanish (24 pages) GP_VD150_CH_Installation_Guide_English-1 (28 pages) GP_VD150_CH_Installation_Guide_English (28 pages) GP_VD150_CH_Operating_Instruction_Chinese-1 (33 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |