Specifications | Manual for the MKS Instruments T3P Pendulum Valve with an Analog/TTL interface T3P Valve Analog/TTL Manual t3P, t3pi, t3pia MKS Instruments |
Business section |

Specifications | Manual for the MKS Instruments T3P Pendulum Valve with an Analog/TTL interface T3P Valve Analog/TTL Manual t3P, t3pi, t3pia MKS Instruments |
Business section |
Specifications | Manual for the MKS Instruments T3P Pendulum Valve with an Analog/TTL interface T3P Valve Analog/TTL Manual t3P, t3pi, t3pia MKS Instruments |
Suggested Link Details/Purchase | |
Content | Setup Chapter Two: Installation 15 Table 6: Maximum Torque Levels When Mounting With the Centering Ring and Spacer Ring Nominal Size Max. Tightening Torque (Nm) Max. Tightening Torque (lbf-ft) mm inch ISO-F JIS ISO-F JIS 320 250 200 160 100 12 10 8 6 4 N/A 17-20 13-15 13-15 8-10 17-20 17-20 13-15 N/A N/A N/A 13-15 9-11 9-11 6-8 13-15 13-15 9-11 N/A N/A Verify that the depth of the mounting screws is maximum 1X thread diameter. StandardSpacer RingRequired Mounting with the O-Ring in Groove Tighten mounting screws of the flanges uniformly in crosswise order. Observe the maximum torque levels in the following table. Higher tightening torques deform the valve body and can lead to an improper function of the valve. Table 7: Maximum Torque Levels When Mounting with the O-Ring in Groove Nominal Size Max. Tightening Torque (Nm) Max. Tightening Torque (lbf-ft) mm inch ISO-F JIS ISO-F JIS 320 250 200 160 100 12 10 8 6 4 N/A 35-40 35-40 35-40 20-23 65-70 65-70 35-40 N/A N/A N/A 26-30 26-30 26-30 15-17 48-52 48-52 26-30 N/A N/A Verify that the depth of the mounting screws is maximum 1X thread diameter. Admissible Forces Forces from evacuating the system, from the weight of other components, and from baking can lead to deformation and malfunctioning of the valve. Stress has to be relieved by suitable means, e.g. bellows sections. Table 8: Admissible Forces Nominal Size Axial tensile or compression force (FA) Bending moment (M) mm inch N lbf Nm lbf-ft 320 250 200 160 100 12 10 8 6 4 3000 2500 2000 2000 1000 660 550 440 440 220 120 100 80 80 40 90 75 60 60 30 FA M For a combination of both forces (FA and M) the values are invalid. Verify that the depth of the mounting screws is maximum 1X thread diameter. |
Navigation | Previous Page / Next Page |
Following Datasheets | T3P-DeviceNet-MAN (76 pages) T3P-RS232-MAN (68 pages) T3Pds (4 pages) T3PIA-DIM (4 pages) T6244R7 (4 pages) T64000 (8 pages) T6822r1-1 (3 pages) T7418 (3 pages) T95-1 (2 pages) Tabell1_2006_slutv_Energivet (1 pages) |
Check in e-portals![]() |
World-H-News Products Extensions Partners Automation Jet Parts |
Sitemap Folder | group1 group2 group3 group4 group5 group6 group7 group8 group9 group10 group11 group12 group13 group14 group15 group16 group17 group18 group19 group20 group21 group22 group23 group24 group25 group26 group27 group28 group29 group30 group31 group32 group33 group34 group35 group36 group37 group38 group39 group40 group41 group42 group43 group44 group45 group46 group47 group48 group49 group50 group51 group52 group53 group54 group55 group56 group57 group58 group59 group60 group61 group62 group63 group64 group65 group66 group67 group68 group69 group70 group71 group72 group73 group74 group75 group76 group77 group78 group79 group80 group81 group82 group83 group84 group85 group86 group87 group88 group89 group90 group91 group92 group93 group94 group95 group96 group97 group98 group99 group100 Prewious Folder Next Folder |